IMAGE FUSING
SM 2-33 G031/G032
Detailed
Descriptions
2.6.7 FUSING TEMPERATURE CONTROL
When the main switch turns on, the CPU turns on the fusing lamp. When the
thermistor detects the ‘ready to print’ temperature (170
°
C), the machine can start to
print at any time. The lamp stays on until the thermistor detects the standby
temperature [A]. Then, the CPU maintains this temperature using on-off control. To
start printing, the CPU raises the temperature to the printing temperature [B] and
maintains it as shown on the next page.
In energy saver mode, the fusing lamp is off.
100
200
170
printin
g
[B]
standb
y
[A]
Main SW on
2 minutes
(°C)
G031D533.WMF