Savin SLP20 Manuel de service Page 262

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 274
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 261
USING A DIMM
G031/G032 A-14 SM
1.4 USING A DIMM
1.4.1 PREPARING THE DIMM
Preparation
In summary, the procedure is as follows:
1. Make a byte-swapped file of the firmware file on a PC.
Use the Byte Swap button in the Stinger Service Utility.
2. Copy this file from the PC to a DIMM card plugged into a G031 or G032 printer,
via a parallel cable.
The computer must be connected to the printer with a parallel cable.
Use either the Stinger Service Utility (for use with Windows systems) or MS-
DOS (use the ‘copy /b’ command).
NOTE: When using the Windows utility, all Windows utility files must be copied to
the same directory.
When using MS-DOS, download the download.hed file first (supplied with
the Stinger Service Utility), then download the controller firmware file.
Byte Swap Procedure
1. Start the service utility (click ‘stinger.exe’ or the SSU icon)
G031X523.PCX
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Vue de la page 261
1 2 ... 257 258 259 260 261 262 263 264 265 266 267 ... 273 274

Commentaires sur ces manuels