1. Start Key
2. Drum Motor
3. Main Motor
4. Belt H.P. Detection
5. QL
6. Charge Corona
7. Development Bias DC
8. Development Bias AC
9. Development Motor
10. Toner Supply Motor
11. Toner Supply Motor
Solenoid
12. Revolver Motor
13. Belt Transfer Charge
14. Revolver HP Signal
Note: 1. Time units are in [ms].
2. Timing is accurate within 20 [ms].
3. Ck1: Checks whether the Bk and M cartriege are present.
Ck2: Checks whether the Y cartridge is present.
Ck3: Checks whether the C cartridge is present
4. The amount of time "X" depends on the position of the revolver unit.
5. This sequence will stop if the cartridge sensor detects no cartridge.
4787
561
1000
2067
1191
1181
Bk Y C Bk
Ck1 Ck2 Ck3
X
4733
5305
3267
3790
3771
3410
1952
2143
2362
TIMING CHART 18 [Sequence for the Revolver H.P. Process]
SM APPENDIX 11-18 A166/A187/A189