General attachment regulations:
• For all attachment wires, cut the wire
sheath to a length of approx. 6 – 8 cm
and unisolate the wires by approx. 10
mm from the ends.
• In the case of flexible cables, provision
must be made inside or outside the
device for strain relief. The wire ends
must be fitted with wire-end sleeves. If
necessary, PG9 screw fittings can be
used for the feedthrough on the 230 V
side.
• The wires are fed into the device
through the designated openings.
• All earth wires must be fixed in the
terminals indicated with “PE” (Earth
potential).
6.1
230 V connections
The following points must be observed for
the 230 V connections:
• Where there is a fixed mains
connection, it must be possible to
interrupt the mains supply to the control
unit outside the control unit by means of
a switch.
Where the mains connection is effected
by means of wire and plug with earthing
contact, this switch may be dispensed
with.
• The control units are designed for
operation with a 230 V /50 Hz mains
supply. The pumps and valves to be
connected must be designed for this
voltage.
• All earth wires must be connected to the
terminals marked PE.
i
The neutral terminals (N) are electrically
connected and are not switched.
i
The switching output (A4) is potential-
free.
i
The switching outputs (A1/A2/A3) are
230 V closers.
6.1.1 Overview: 230 V connections for SDC 306
The table below shows the allocation of
switching outputs for the different system
types. The fields with a grey background are
essential to the basic functions of the
system. The white fields are designed for
optional additional functions.
Configuration Switching outputs
Type
Description Output Description
A1
Solar circuit pump
--
1
1 collector array, 1 storage cylinder
--
A1
Solar circuit pump
A2
Anti-Legionnaire’s disease pump
2
1 collector array, 1 storage cylinder,
auxiliary heating, anti-Legionnaire’s
disease
A4
Auxiliary heating
A1
Solar circuit pump
A2
Circulation pump
3
1 collector array, 1 storage cylinder,
auxiliary heating, circulation
A4
Auxiliary heating
A1
Solar circuit pump
A2
Transfer pump
4
1 collector array, 2 storage cylinders,
thermal transfer, auxiliary heating
A4
Auxiliary heating